• Sectional charge/discharge; supports lead-acid & lithium batteries with dual activation. • Hybrid/grid‑connected with anti‑backflow; battery-less solar+grid operation. • Four charging modes plus power-saving mode. • Dual output (inverter/bypass) for uninterrupted pure sine-wave UPS. • Full digital SPWM control & dual MPPT (99.9% efficiency). • 360° protection and intelligent cooling (variable-speed fan, AC switch).
System Diagram

| SMP-H 5.6-12kW Series Off Grid Hybrid Inverter | |||||
|---|---|---|---|---|---|
| Models | SMP-H-5648-60P | SMP-H-6248-60P | SMP-H-8048-110P | SMP-H-11048-110P | SMP-H-12048-120P |
| Parallel mode | |||||
| Permitted parallel number | 1~6 | ||||
| AC Input | |||||
| Rated input voltage | 220/230Vac | ||||
| Input voltage range | (170Vac~280Vac)±2% (90Vac-280Vac)±2% |
||||
| Frequency | 50Hz/60Hz(Auto detection) | ||||
| Frequency Range | 47±0.3Hz~55±0.3Hz(50Hz); 57±0.3Hz~65±0.3Hz(60Hz); |
||||
| Overload/short circuit protection |
Circuit breaker | ||||
| Efficiency | >95% | ||||
| Conversion time (bypass and inverter) |
10ms(typical) | ||||
| AC reverse protection | Yes | ||||
| Maximum bypass overload current |
40A | 60A | |||
| Inverter mode | |||||
| Output voltage waveform | Pure sine wave | ||||
| Rated output power(VA) | 5600 | 6200 | 8000 | 11000 | 12000 |
| Rated output power (W) | 5600 | 6200 | 8000 | 11000 | 12000 |
| Power factor | 1 | ||||
| Rated output voltage (Vac) | 230Vac | ||||
| Output voltage error | ± 5% | ||||
| Output frequency range (Hz) | 50Hz±0.3Hz/60Hz±0.3Hz | ||||
| Maximum Efficiency | >92% | >93% | |||
| Overload protection | (102%<load<125%)±10%:report error and turn off the output after 5 minutes; (125%<load<150%)±10%:report error and turn off the output after 10 seconds; Load>150%±10%:report error and turn off the output after 5 seconds; |
||||
| Peak power | 11000VA | 12000VA | 16000VA | 22000VA | 24000VA |
| Loaded motor capability | 3HP | 4HP | 5HP | 7HP | 8HP |
| Output short circuit protection | Circuit breaker | ||||
| Bypass circuit breaker pecification |
40A | 63A | |||
| Rated battery input voltage | 48V(Minimum starting voltage 44V) | ||||
| Battery voltage range | 40.0Vdc~60Vdc±0.6Vdc (Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery...settable on LCD screen) |
||||
| Power saving mode self- consumption |
Load≤25W | Load≤50W | |||
| Battery Parameter | ||||
| Battery type | Lead acid or lithium battery | |||
| Maximum charge current (can be set) |
80A | 120A | 150A | |
| Charge current error | ± 5Adc | |||
| Charge voltage range | 40~60Vdc | |||
| Short circuit protection | Circuit breaker and blown fuse | |||
| Circuit breaker specifications | 40A | 63A | ||
| DC Input | ||||
| MPPT way | 1 | 2 | ||
| Maximum PV open circuit voltage |
500Vdc | |||
| PV operating voltage range | 120~500Vdc | |||
| MPPT voltage range | 90~450Vdc | |||
| Battery voltage range | 40~60Vdc | |||
| Maximum PV input power | 6000W | 5500W+5500W | 6000W+6000W | |
| Maximum PV input current | 22A | 22A+22A | ||
| PV charging current range (can be set) |
0~100A | 0-150A | ||
| Charging short circuit protection |
Blown fuse | |||
| Wiring protection | Reverse polarity protection | |||
| Hybrid charging Max charger current specifications(AC charger+PV charger) | ||||
| Max charger current (can be set) |
0~100A | 0~150A | ||
| General Data | ||||
| Certification | CE(IEC62109-1,2) | |||
| EMC certification level | EN61000,C2 | |||
| Operating temperature range | -15℃~55℃ | -10℃ to 55℃,>45℃ drop runs | ||
| Storage temperature range | -25℃~60℃ | -25℃~55℃ | ||
| Humidity range | 5%to 95%(Conformal coating protection) | |||
| Noise | ≤60dB | |||
| Heat dissipation | Forced air cooling,variable speed of fan | |||
| Communication interface | USB/RS485(MiFi/GPRS)/Dry contact control | |||
| Size (L*W*D) | 415mm*280mm*100mm | 540mm*350mm*120mm | ||
| Weight(kg) | 7.8 | 19.5 | ||
We usually reply within 12 hours